Temperature Testing Facility - Cameron
JTS was contracted to provide a temperature testing facility for the valves and actuators manufactured by Cameron (oil & gas industry). The temperature range required was -75° C to +180°C (with occasional use at +205°C). The facility consisted of a temperature enclosure (external size 2.8m x 2.3m x 2.3m), temperature conditioning unit (external size 2.4m x 2.0m x 2.0m) and external plant unit. The roof had to be removable by overhead crane, and the upper and lower "zones" of the chamber separately controllable. Other features included over temperature safety, multi glazed high temperature window and oil sump.