RCD Isolation Box 400V
[MBRCD400ISOL]
New Master Box to Test RCDs That will NOT TRIP the Building Supply RCD - Guaranteed Tests are carried out by Plugging the RCD Test Box into a Building 13a, 16a, 32a, or 63a 230V Socket, or a 400V 3 Phase 5 Pin Socket (or other Varieties with Adaptors) Socket either RCD Protected or not without fear of Tripping the Building RCD as the Test Box is Fully Isolated The RCDs will plug directly into the Sockets mounted on the Box & the RCD Tester into the RCD Socket Types of RCD: 2000 Electrical Test Bay RCD 230V Plug in 230V, In-Line 230V, Box Mounted 230V Adapters are available as required These Adapters can also be used for Box Mounted and in-line RCDs so the RCD Tester can be Plugged in after the RCD A carrying Handle is fitted to ease Mobility The Blue LED Indicator confirms Power in and the 2 Red LEDs indicate the secondary Voltage. The Red, Yellow & Blue Lamps indicate that the 3 Phase is in use The outputs are protected by a 3a Fuse next to the Red LED Indicators Socket Outlets on the Box are 13a, 16a, 32a, & IEC 230V + 32a 5 Pin 400V The Primary is protected by a 3a Fuse and the 3 Transformer Outputs are protected by a T160ma Fuse. The Box is Vented Supply Leads (2) 5 Core 1.5mm H07RN-F Cable 2 Metres Nominal fitted with 32a 5 Pin 400V 3 Phase Plug & 32a 5 Pin 400V 3 Phase Coupler 3 Core 1.5mm H07RN-F Cable 2 Metres Nominal, 16A 230V Plug to 16A 230V Trailing Socket 32a 230V 3 Pin Plug to 16A 3 Pin 230V Trailing Socket Adapter 13a 230V Plug to 16a 3 Pin Trailing Socket Adapter. The Box is not suitable and should NOT be used as an Extension Lead or Adapter of any kind. It is designed to be ONLY used as and Adapter for Testing RCDs. For Testing 3 Phase RCDs Phase by Phase you will also need MasterBox 3#RCD 3 (search 3#RCD) 3 Phase to Single Phase & 3 Phase RCD Adaptor
New Master Box to Test RCDs That will NOT TRIP the Building Supply RCD - Guaranteed Tests are carried out by Plugging the RCD Test Box into a Building 13a, 16a, 32a, or 63a 230V Socket, or a 400V 3 Phase 5 Pin Socket (or other Varieties with Adaptors) Socket either RCD Protected or not without fear of Tripping the Building RCD as the Test Box is Fully Isolated The RCDs will plug directly into the Sockets mounted on the Box & the RCD Tester into the RCD Socket Types of RCD: 2000 Electrical Test Bay RCD 230V Plug in 230V, In-Line 230V, Box Mounted 230V Adapters are available as required These Adapters can also be used for Box Mounted and in-line RCDs so the RCD Tester can be Plugged in after the RCD A carrying Handle is fitted to ease Mobility The Blue LED Indicator confirms Power in and the 2 Red LEDs indicate the secondary Voltage. The Red, Yellow & Blue Lamps indicate that the 3 Phase is in use The outputs are protected by a 3a Fuse next to the Red LED Indicators Socket Outlets on the Box are 13a, 16a, 32a, & IEC 230V + 32a 5 Pin 400V The Primary is protected by a 3a Fuse and the 3 Transformer Outputs are protected by a T160ma Fuse. The Box is Vented Supply Leads (2) 5 Core 1.5mm H07RN-F Cable 2 Metres Nominal fitted with 32a 5 Pin 400V 3 Phase Plug & 32a 5 Pin 400V 3 Phase Coupler 3 Core 1.5mm H07RN-F Cable 2 Metres Nominal, 16A 230V Plug to 16A 230V Trailing Socket 32a 230V 3 Pin Plug to 16A 3 Pin 230V Trailing Socket Adapter 13a 230V Plug to 16a 3 Pin Trailing Socket Adapter. The Box is not suitable and should NOT be used as an Extension Lead or Adapter of any kind. It is designed to be ONLY used as and Adapter for Testing RCDs. For Testing 3 Phase RCDs Phase by Phase you will also need MasterBox 3#RCD 3 (search 3#RCD) 3 Phase to Single Phase & 3 Phase RCD Adaptor
For more information on RCD Isolation Box 400V [MBRCD400ISOL] talk to 2000 Test Equipment Ltd
Enquire Now
List your company on FindTheNeedle.