Find The Needle Get Listed

KX2-4084/T3/BCE-11

Product Code: KX2-4084/T3/BCE-11

KX2-4084/T3/BCE-11

KX heaters can be installed in areas where explosive gases may be present and are suitable for hazardous Zone 1 and Zone 2. They need to be mounted with the terminal enclosure in a horizontal position and should be operated in ambient temperatures not exceeding 40°C.

Heaters labeled T3 can be installed in areas designated T3, T2, or T1. Heaters stamped T4 can be installed in areas designated T4, T3, T2 or T1.

Common applications include:

• Control cabinets and small enclosures.

• Storage rooms for paints and cleaners.

• Grain elevators.

• Flour mills.

• Spray booths.

• Gas plants.

• Pump houses.

• Marine and offshore.

• Oil platforms.

• Cleaning and dyeing plants.

Features:

• ATEX certified.

• Extended surface area black anodised copper free aluminium heat emitter with nickel-plated guard.

• Universal support bracket for wall or floor mounting.

• Slide out terminal block trolley simplifies installation and servicing.

Options:

• Built-in externally adjustable thermostat (add suffix T)

• ATEX approved wall mounted EExd thermostat. Ref. KEX-1.

Key features:

  • 0.84kw heating capacity
  • 110v 1ph supply
  • T3 Temperature T-Class
  • Double emitter 410mm wide
  • Overall height 594mm

Additional information:

  • Brand: Kaloric
  • Warranty: 1 year manufacturer's warranty
  • Delivery: Dependent on stock availability. Check with us before ordering