Sanitizer & Biocide for Heat Pump Systems
Although the life expectancy of a ground source heat pump is typically 20-25 years - without the correct water treatment the system will be liable to problems leading to costly call backs for the installer and householder. For example, for new build applications, ground source arrays are installed during the ground work period when the foundations are laid. These arrays are often filled with water or left while construction continues. In these conditions, the water is stagnant and bacterial contamination or microbiological growth can quickly develop, having a negative effect on the efficiency of the system. In the worst cases, this can lead to failure of the ground source heat pump within a few months if the bacteria contaminate the heat transfer fluid. Protection is vital and Sanitizers/Biocides have been developed to clean and disinfect ground arrays from the potential damaging effects of bacterial slime and other contaminants before commissioning. In addition, many installers are unaware of the danger of not dissolving heat pump fluids properly. If the heat transfer fluid isn't sufficiently dissolved, sections of water can be left unprotected, leading to corrosion, damaged pipe work and even pump failure if these sections of water, with no frost protection, come into contact with the heat pump. Rather than just pouring the heat transfer fluid into the water it is mixed in accordance with the manufacturer’s instructions into a mixing machine and pumped through the system at the same time as the system water. Installers can ensure the heat transfer fluid has been fully dissolved by using a Refractometer, which can determine the concentration levels. Easy to use, the installer simply opens the illuminator plate and places a drop or two of sample water onto the prism. One the plate is closed; the installer looks through the circular eyepiece to take a visual reading of the level of frost protection within the system. This reading can then be cross-referenced with manufacturer’s recommendations to ensure the system is fully protected. The benefits of cleaning and protecting renewable technologies are likely to be further recognised in the revisions to Part L of the Building Regulations in 2010. In the proposed changes to the regulations when it comes to heat pumps, it states 'ground loops should be cleaned with a cleaning fluid and biocide as part of the commissioning process.' So it is advisable that installers ensure best practice sooner rather than later. Is £0.10 per metre worth compromising yourself and your clients...?? (based on 40mm SDR11 collector pipe) Go Geothermal stock Sanitizers, Heat Transfer Fluids, (Air & Ground Source) Test Kits & Refractometers

For more information on Sanitizer & Biocide for Heat Pump Systems talk to Go Geothermal Ltd

Enquire Now

  Please wait...

Location for : Listing Title