Lyotherm3: The cutting edge in frozen state solution analysis
Frozen solutions are a critical step in many industries such as food storage, pharmaceuticals, biotech and freeze drying (lyophilisation). Understanding the critical temperatures for each solution can help to improve the longevity and efficacy of the processes that use this phase. For example, storing foods above their softening transition may result in faster rates of degradation, and in lyophilisation, primary drying above the glass transition can result in collapsed cakes. On the other side of optimization, operating at lower temperatures than is required leads to longer processing times, and thus inefficiency; having detailed and clear analysis data allows the determination of clear parameters that increases efficiency and productivity. What is the Lyotherm and how can it help? The Lyotherm is a unique combination of an emerging analytical technique, impedance analysis, combined with traditional differential thermal analysis (DTA). These techniques use two different perspectives to enhance the analysis data providing an extra dimension to the information allowing for greater detail and more informed decision making. Electrical Impedance: Impedance combines capacitance, inductance and resistance into one metric that relates to molecular mobility within the sample. This identifies softening, stabilization, crystallization, glass transitions, melting and other phase changes. DTA: Identifies the thermal signature of events by comparing the temperature of the sample to a reference. Identification of exo/endotherms, glass transitions and melting events gathers more information on the events seen with impedance. Thermal Techniques The DTA analysis technique is a close cousin of modulated differential scanning calorimetry (mDSC), the crucial difference being the source of the difference between the sample and reference. In DTA analysis, the heat flow is kept constant and the temperature measured, while in mDSC the heat flow is recorded while temperature is constantly compensated for to keep it at the same heating rate. The mDSC is one of the most sensitive techniques in frozen state solution analysis, and yet wasn’t designed for it – merely adapted. By targeting the frozen state with the novel impedance technique, the Lyotherm can show far more about a solution than even mDSC. A few of these comparisons will be drawn below, showcasing the power of the Lyotherm. Isothermal Glass Transitions One of the major advantages of the Lyotherm is the increased sensitivity to minor reorientations and thus glass transitions. The small ‘kink’ in the diagram at circa -30°C is indicative of this phase transformation. These are often very difficult to see in the mDSC due to their tiny heat flow signatures, as the DTA curve below also demonstrates – the line shows no sign of the associated thermal transfer that may be expected with this event due to its magnitude. In mDSC (Figure 2) there is no sign of the glass transition with this sample. The midpoint version of the analytical method traditionally used in mDSC (especially with glass transitions) is dependent on how vigorous the exothermic / endothermic change is, as the heat evolved will directly contribute to the size and spread of the event. For this reason DTA and Impedance strictly use onset as a conservative estimate of the point the phase transition occurs at. Layers of Information The Lyotherm’s extra dimension of analysis can be seen in this sample, with an event visible in both mDSC and Lyotherm having a greater volume of information in the latter. The Lyotherm shows two events (Figure 3): the onset of an exothermic event (in DTA) that is linked to a small stabilization in the impedance curve at -67.3°C. The second event is a softening from -53.0°C to -30.4°C that results in maximum mobility in the sample. This mobility increase then triggers a slow melting process, seen again in the DTA curve. In the mDSC (Figure 4) the analysis of this event would be very different due to the lack of impedance data. The onset of slow melt (-51.1°C) correlates well with the -53.0°C seen in the Lyotherm data but doesn’t distinguish one element fully mobilizing in the solution as can be seen in impedance. The signal may also be confused with the very shallow exotherm in the non-reversible heat flow curve which occurs at a similar point to that seen in DTA, without the critical inclusion of the impedance data that shows it is related to a preceding stabilization event and shouldn’t be associated with the slow melt. From the Lyotherm analysis we can see that this is precisely the event to be cautious of, as the onset of softening and finally maximum mobility, can be seen to start with it. During annealing this upper level of mobility (-30.4C) is the critical temperature to hold over to allow for the Ostwald ripening of the ice crystals potentially raising the critical temperature. In the mDSC (Figure 4) the analysis of this event would be very different due to the lack of impedance data. The onset of slow melt (-51.1°C) correlates well with the -53.0°C seen in the Lyotherm data but doesn’t distinguish one element fully mobilizing in the solution as can be seen in impedance. The signal may also be confused with the very shallow exotherm in the non-reversible heat flow curve which occurs at a similar point to that seen in DTA, without the critical inclusion of the impedance data that shows it is related to a preceding stabilization event and shouldn’t be associated with the slow melt. From the Lyotherm analysis we can see that this is precisely the event to be cautious of, as the onset of softening and finally maximum mobility, can be seen to start with it. During annealing this upper level of mobility (-30.4C) is the critical temperature to hold over to allow for the Ostwald ripening of the ice crystals potentially raising the critical temperature. Corroborated and Superceded In the Lyotherm this sample also behaves in a complex manner but a key difference is the slope of the Zsinφ line before and after the transition, the gradient of which changes slightly. This suggests that the event is a glass transition which alters the heat capacity and thus the rate of softening in the structure. The onset of the event is -31.4°C which correlates closely to the onset given by mDSC (Figure 6). The exothermic event begins at -26.6°C which also agrees with the mDSC exotherm shown. The mDSC fails to pick up on the preceding exotherm with an onset of -54.1°C, which also doesn’t have a detectable effect on the Zsinφ graph. Since the DTA reaches a new baseline post-event it is possible that the onset at -53.4°C is the beginning of a new baseline due to a very minor enthalpic relaxation which isn’t seen in mDSC. The Next Generation in Analysis: Lyotherm3 The new Lyotherm3 has been developed specifically to meet the analysis challenges that those working with analytical data for frozen state solutions encounter including the need for a higher impedance ceiling for early transitions in particular. The following table explains the analytical improvements offered by the Lyotherm3; an optional impedance only set-up will be available soon. The major Lyotherm3 benefits are to be found in the user experience, such as a new enclosure design that allows for easier verification of status. Operation is now much easier with no need for raising and lowering the block, and cabling has been bundled into a simpler set up for corrective action. To read the full article please visit our website

For more information on Lyotherm3: The cutting edge in frozen state solution analysis talk to Biopharma Group

Enquire Now

  Please wait...

Location for : Listing Title