Product Code: AEP450EP Series
The AEP450EP Series is our AC V/I input transducer range suitable for a wide range of AC Current or Voltage signal monitoring applicationsInput AEP451EP / AEP453EP: AC current: up to 5A max Typical input range: 0-1A or 0-5A ac.Input AEP452EP / AEP454EP: AC voltage: up to 300V max Typical input range: 0-100Vac or 0-220Vac.Output DC current or voltage available in the range of 0-20mA, 4-20mA (dc) into 650 ohms max load. 0-5V, 1-5V, 0-10V, 2-10V (dc) into 1.5Kohms min.Typical output range:AEP451EP / AEP452EP; 1x 4-20mAAEP453EP / AEP454EP; 2x 4-20mA (o/p2 terms: 7+,8-)
Environmental Condition
Performance
Mounting / Dimensions
Environmental Condition
Storing temperature: -20°C to +70°COperating Ambient: -5°C to +60°CRelative Humidity: 5% to 95% RH (Non-Condensing)
Performance
Response time: <400mSAccuracy: <±0.5%Supply regulation: ±20%Supply consumption: <3.5VA
Mounting / Dimensions
Screw terminal blocksEnclosure 22.5w x 75h x 105d mmMounting: Din rail (TS35)Weight: <250g
For more information on AEP450EP Series AC V/I Input Transducers talk to Amelec Instruments