Valve Test Rig
Specialised valves for the Petrochemical and Natural Gas industries require extensive performance and qualification testing to meet international standards such as API Specification 6A, Appendix F, PR2 level and ISO10423:2001.
Test procedures define a sequence of valve operations at varying upstream and downstream pressures, varying valve positions and varying ambient and valve body temperatures from -40°C to 160°C.
A legacy valve test rig had operated in manual mode only and although it had previously been upgraded by another company for automatic running this had not been achieved. This was found to be due to poor temperature control and lack of adequate control software and a new system was supplied to address these issues.