Find The Needle Add My Company
How is Approved Doc E Testing completed?
Airborne sound insulation test (walls & floors): A controlled noise is generated by an amplifier and loudspeaker across a broad range of frequencies. The generated noise is very loud and can be in excess of 100dB. Initial measurements are taken using a Sound Level Meter within the ‘source room’ followed by further measurements in the ‘receiver room’ on the other side of the wall or floor under investigation. The source room speaker position is then changed and the measurements repeated either side of the partition under test. Background noise measurements are made using a sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the characteristics and absorptiveness of the room.

For more information on How is Approved Doc E Testing completed? talk to Soundguard Acoustics Ltd

Enquire Now

  Please wait...

Location for : Listing Title