Find The Needle Add My Company

Current Transducers-Premo-DCT200Amp

Product Code: DCT200A Current Transducer

Current Transducers-Premo-DCT200Amp
* High Accuracy over high bandwidth. * Very low output noise and offset drift. * Negligible insertion losses. * High immunity to interference. * Overload Capability. * Excellent linearity. General Data: * Operating Temperature: -20 to 70 ºC * Storage Temperature: -20 to +85 ºC * Weight: 300g * Primary Diameter Hole: < 12mm * Basic Insulation (Between Primary and Measurement Current): 3500 V AC 50Hz 1' * Fault Operation Condition (Led Power Off): Ip > 120% * Compensation Winding Maximum Resistance (T= 70ºC): 40 Ohm * Lenght Two Wire Cable to R Burden (Connected between pin 1 and 3): 50cm (typical) Accuracy: * Accuracy at Ip (T=25ºC): < 0.1% * Linear Error ( Beetwen 50 to 200 A) Vcc = ±15V, Rb = 2.7 Ohm: < 5 ppm * Linear Error ( Beetwen 10A to 50A ) Vcc = ±15V, Rb = 27 Ohm: < 10 ppm * Linear Error ( Beetwen 0.01 to 10A ) Vcc = ±15V, Rb = 50 Ohm: < 50 ppm * Offset Current: 5uA Max * Offser Current Temperature Drift: < 5 ppm/ºC * Time Response ( 10% to 90% of Ip): <1us * di/dt Followed Accurately: > 100A/us * Frequency Bandwidth ( Ip = 10A DC): DC to 100kHz ( -3dB ) Applications: * AC variable speeds drives and servo motors. * Battery supplied applications. * Uninterruptable Power Supplies (UPS). * Static converters for DC motors. * Switch mode power supplies (SMPS). * Power supplies for welding applications. According To: * UNE EN 50178 * UNE EN 50155

For more information on Current Transducers-Premo-DCT200Amp talk to Power Products International Ltd

Enquire Now

  Please wait...

Location for : Listing Title