Find The Needle Get Listed
Ajax EN54 FireProtect (Smoke/Sounder) (8EU) ASP - Black
EN54 FireProtect Jeweller detectors Wireless addressable point smoke detector combined with a fire alarm sounder � Compare product versions EN54 FireProtect (Smoke) Jeweller EN54 FireProtect (Smoke/Sounder) Jeweller EN54 FireProtect (Heat) Jeweller EN54 FireProtect (Heat/Sounder) Jeweller EN54 FireProtect (Heat/Smoke) Jeweller EN 54-7 EN 54-25 BOSEC SBSC DBI EN 54-7 EN 54-3 EN 54-25 BOSEC SBSC DBI EN 54-5 EN 54-25 BOSEC SBSC DBI EN 54-5 EN 54-3 EN 54-25 BOSEC SBSC DBI EN 54-5 EN 54-7 EN 54-25 BOSEC Smoke detection Smoke detection --- --- Smoke detection --- --- Heat detection Heat detection --- --- Audible alarm --- Audible alarm --- � Rules met. Conventions shattered. EN54 FireProtect Jeweller detectors combine certified reliability with effortless installation. This wireless series includes addressable point smoke and heat detectors, some of them combined with built-in fire alarm sounders. Each detector provides best-in-class detection accuracy thanks to Ajax's patented smoke chamber with a dual-spectrum optical sensor and two accurate thermistors. With built-in communicators, long battery life, and stable radio communication, the devices are ready for different-scale projects. No need to open the enclosure or run cables � installation and configuration take just minutes via Ajax apps. Early service notifications and automated maintenance reports via Ajax PRO Desktop ensure the system stays easy to support for years. Built to stand out Advanced threat detection with patented hardware and proprietary software Fast installation with the SmartBracket mounting panel and setup via Ajax apps Built-in radio communicators providing up to 1,700 m communication range with EN54 Fire Hub Jeweller Multiple models to meet the needs of any project � Future-proof hardware Minimalist design with hidden sensors and sounders SmartBracket panel allowing for device rotation up to 90 degrees Battery covers designed for easy replacement� Locking mechanism to limit attempts at detaching the device Detection without compromise EN54 FireProtect Jeweller detectors meet EN 54 standards and combine the best available technologies to achieve unmatched accuracy, avoiding possible false alarms. Smoke detection The unique smoke chamber, dual-spectrum optical sensor, and proprietary HazeFlow 2 software algorithm guarantee the speed and accuracy of fire detection. The smoke chamber is hardwired with a dual-spectrum optical sensor that has blue and infrared LEDs with different wavelengths. It measures the microparticle concentration in the air to determine the size of the volatile particles inside the chamber and responds only to smoke. The HazeFlow 2 algorithm analyses and compares data from the dual-spectrum optical sensor to a specified pattern to define smoke from vapor or steam. The detector instantly raises the alarm when pattern dynamics indicate a real case of fire. Heat detection Two built-in thermistors detect a rapid temperature rise or threshold exceedance. They trigger an alarm when a rapid temperature increase or static temperature is detected. Heat detector modes � A1, A1R, A1S, B, BR, BS, C, CR, CS, or a fixed temperature2 � can be selected in an Ajax app. This approach ensures fast and accurate detection of flaming fires or heat build-up caused by smouldering, which is critical for timely response. Tailored detection with EN54 FireProtect (Heat/Smoke) Jeweller EN54 FireProtect (Heat/Smoke) Jeweller supports multiple detection modes to adapt to different site requirements. In the default combined detection mode, one sensor is selected as primary, while the sensitivity of the secondary one is dynamically adjusted. As signs of fire develop, the detector lowers the activation threshold of the second sensor to confirm the event. This mode enables fast and reliable alarm verification while reducing false alarms caused by non-fire factors, such as steam or temporary temperature changes. In independent detection mode, both smoke and heat sensors operate separately, so an alarm is triggered as soon as either sensor detects signs of fire, ensuring the fastest response. Additionally, the detector can operate in smoke-only or heat-only mode. Combined detection One sensor acts as primary, while the second one confirms the alarm. Heat and smoke Each sensor works independently and can trigger an alarm. Heat Only the heat sensor is active. Smoke Only the smoke sensor is active. Fast, intuitive, and error-free setup EN54 FireProtect Jeweller detectors are ready to operate straight out of the box. An installer can mount the device in 5 minutes using the SmartBracket panel without opening the enclosure. The panel offers up to 90� for device rotation for perfect alignment. Arrows indicate the correct LED orientation. Ajax apps help quickly make the device a part of the ecosystem: just scan the QR code, assign a room and a zone, and specify the device location for easier maintenance and identification. The parameters from a device profile are always up-to-date and instantly available via Ajax apps. All settings are configured via toggles in an intuitive interface, eliminating the risk of human error. Connection Installation Setup Adding to a security system via QR code SmartBracket panel with an adjustable rotation angle � no need to disassemble the enclosure Configuring via toggles in Ajax mobile and desktop apps � Reliable wireless communication EN54 FireProtect Jeweller detectors come with a built-in radio communicator � no additional modules or wiring are needed. The Ajax system uses two-way secure radio communication based on the Jeweller proprietary protocol. Devices maintain a stable connection with the control and indicating equipment (CIE) at distances1 of up to 1,700 meters, and can operate through a radio signal range extender. The alarms reach the CIE in just 3 seconds. The system optimizes power consumption to extend battery life, automatically adjusting the maximum power of radio transmitters in devices. The Ajax CIE uses radio hopping to protect against radio interference and signal interception. It also detects communication loss with a device in seconds, instantly notifying the monitoring station and users. Up to 1,700 m of radio communication with a CIE or range extender 3-second alarm delivery Built-in radio communicator Frequency hopping and jamming detection Long-lasting power autonomy The detectors are powered by pre-installed batteries that provide up to 5 years of autonomous operation. They report low batteries in advance. Installers and users get notifications from Ajax apps. EN54 FireProtect Jeweller detectors also indicate low battery levels through LED indication and audible beep, keeping everyone informed on-site. Thanks to battery covers, replacement is quick and tool-free � no need to disassemble the detector. Tool-free battery swap Low battery level notification in advance Up to 5 years of autonomous operation Maintenance without the hassle Remote system and device monitoring All Ajax devices perform automatic self-diagnosis and report their states to the CIE. Essential parameters, including tamper alarm, communication, power supply, and sensor statuses, are continuously monitored. All the notifications and reports are available in Ajax PRO Desktop. The system sends early alerts, helping plan maintenance visits and optimize technician workload. Automated maintenance reports Security professionals can generate and download detailed reports on the status of all system devices. This allows them to identify maintenance needs without on-site visits and improve efficiency. Industry-standard testing support EN54 FireProtect Jeweller detectors are compatible with Solo 332 and other popular Smoke aerosols. In Test mode, filtering algorithms are turned off so the detector reacts to the sprayed smoke particles that replicate the conditions of smoke from a fire. Tool-free battery replacement Each detector features battery covers for quick battery replacement without device removal or disassembly.

Firesense is a leading independent UK distributor of fire detection, fire safety and security equipment, supporting professional installers and businesses across the country. Established in 1992 and based in Tunbridge Wells, the company has more than 30 years of experience within the fire and security industry.

Originally founded as a specialist manufacturer of conventional fire alarm control panels, Firesense has developed into a comprehensive supplier of fire detection, security, emergency lighting and life safety products. The company works with a wide range of recognised manufacturers, helping customers access reliable equipment for projects of different sizes and requirements.

Firesense supplies conventional, addressable, wireless and two-wire fire alarm systems alongside detectors, control panels, manual call points, sounders, cables, batteries, emergency lighting, fire alarm testing equipment and related accessories. Its expanding security range also includes CCTV, intruder alarm, access control and smart security solutions.

A key strength of Firesense is its experienced technical and account management team. Customers can receive practical product guidance and support when selecting equipment, designing systems or resolving technical enquiries. As an independent distributor, Firesense can recommend suitable products from across its available ranges rather than being restricted to a single manufacturer.

With extensive stock held at its Tunbridge Wells distribution centre, Firesense aims to provide fast and reliable nationwide supply, including rapid dispatch and trade counter collection.

For fire detection, security or life safety equipment, visit the Firesense website or speak with their experienced team for product advice, availability and help with your enquiry.

For more information on Ajax EN54 FireProtect (Smoke/Sounder) (8EU) ASP - Black talk to Firesense Limited

  Please wait...

Location for : Listing Title