The importance of a battery backup in a Type C Waterproofing System
The importance of a battery backup in a Type C Waterproofing System When addressing the risks involved in a pumped Type C Waterproofing System, ‘mains failure’ falls within the top 5 categorised risks. Submersible pumps installed as part of a Type C system require mains power to operate, typically single-phase (240V). Battery backup systems for basement pumps are a critical inclusion in all good Type C drained protection system design along with appropriate pumps and high-level alarms. If the Type C drained protection system is designed correctly and the structure is ‘locked down’ in accordance with section 10.1 BS8102:2009, the pumps should only deal with ‘seepage’ and in turn, run minimally. It is this guidance from BS8102:2009 that makes it crucial a battery backup consumes very little power when in ‘standby’ mode. A mains failure can occur for a multitude of reasons. Below are the most ‘common’: Loss of power locally within the property (a few hours?). Normally caused by a tripped fuse (overload, lightning, faulty installation, etc.) Total loss of power to a broader geographic area (a few days?). Normally caused by a storm, grid failure, temporary downtime during works, etc Pumps being switched off by mistake. As part of the PCA’s ‘Best Practice Guidance for Type C Waterproofing Systems’, they recommend the inclusion of a battery backup into the design and the NHBC (National House-Building Council) state a secondary pump with a battery backup should be included in all pump systems. This white paper will address the risks involved in not having a battery backup installed and the reason why we are taking the bold move to get uninterrupted power supplies seen as an industry standard for all Type C waterproofing projects. Statistics The graph above is an indicator of the reliability and availability of the electricity distribution network. It shows the number of interruptions experienced by customers and the average length of interruptions – correct as of March 2019. In London, East Anglia & South East England the total amount of downtime per customer in a 12-month period was 32 minutes. This graph also indicates that 36% of people in those areas were affected by a power failure at some point in 12-months. What is the risk? The risk of not having a battery backup installed as part of the waterproofing system is the risk of a potential flood. If a basement construction is poor or the fabrication of the basement fails over time, the level of ‘seepage’ can become much higher. With higher levels of seepage, comes more elevated levels of risk in general, but even more so during a mains failure. This is due to the pumps working more frequently to cope with the raised levels of water ingress. Other basements being constructed in an area where there are pre-existing basements can also influence groundwater ingress through the structure (sometimes more and sometimes less). The graph above shows the steady downward trend in cycles per hour over a 6-month period. During this period, the property next door to the ‘monitored’ property with a pump station was excavating a basement. The data show the construction has influenced the groundwater course and drastically reduced the cycles per hour from 11 to 0.3 Minimising & Mitigating Risk The way to minimise and mitigate the risk of flooding during a mains failure is to install a battery backup to power the pumps. There are lots of uninterrupted power supplies on the market, but most were not originally designed to work with pumps – they have been repurposed from other industries (IT, Marine, etc.). The main issue with repurposed battery backups is that they are designed to provide power instantaneously upon sensing a mains failure. In most cases, pumps do not require power instantly or continuously. They only require power when the float arm that controls the pump and turns it on and off is in the UP position. From a sample of 173 remotely monitored groundwater pump stations, the mean average cycles per day = 7.92. This equates to 0.33 cycles per hour. Based on these statistics, the PowerMaxx will run a V3 pump for just over 6 days (as seen in the graph above). The Delta Membranes PowerMaxx family is purpose designed and manufactured for submersible pumps. The PowerMaxx has a facility called ‘Dynamic Polling’, this enables the battery backup to achieve standby times that greatly exceed any of its nearest rivals. Dynamic Polling effectively allows the PowerMaxx to enter a ‘sleep’ mode every 2 minutes, it then checks to see if the pump requires power, if it does, the battery backup will provide power until the float is down, if it doesn’t, it will then continue ‘polling’ until the pump does require power. The PowerMaxx also features automated recharging, which means after every power failure, the battery will recharge when the mains power is present again. This means the battery backup is always ready to provide power. Summary With all this in mind, the installation of a PowerMaxx (or another battery backup from our range) will reduce the risk of flooding considerably by allowing weeks of standby and days of run times. This solution ultimately provides the homeowner with total peace of mind that they can be away from their property without having to worry about power failures. As mentioned in the introduction, when factoring a battery backup into a waterproofing project, don’t forget that it’s not just grid outages that cause power cuts. Storms, local electrical faults (within the property) and human error all must be factored in. While all these events may only happen once in a blue moon, they do happen and it’s essential to have a failsafe in place to protect the basement and other assets.

For more information on The importance of a battery backup in a Type C Waterproofing System talk to Delta Membrane Systems Ltd - Basement waterproofing

Enquire Now

  Please wait...

Location for : Listing Title