Find The Needle Add My Company
How well are you controlling your NO2 in your Road Tunnel?
NO2 Control in Road Tunnels The need to minimise NO2 exposure in road tunnels has been inhibited by the lack of suitable, low-maintenance sensors for measuring ppb levels of NO2. Recent improvements in technology have resulted in the introduction of not one but two competing techniques designed specifically for this application, making the possible control of tunnel NO2 levels a reality rather than just a desire. NO2 should now be a key control parameter. NO2 is particularly toxic. Levels higher than 1ppm can be harmful to healthy people. Lower levels as low as 0.1ppm will harm asthma sufferers. Current ventilation strategies based upon CO and visibility are inadequate. It is assumed that if safe operating CO levels are maintained then other gaseous emissions will also be safe. CO levels are now too low to be an appropriate control parameter. The introduction of catalytic converters has produced a major reduction in exhaust CO emissions. CO levels in tunnels rarely exceed the ventilation control trigger points. NO is not considered to be a harmful pollutant in tunnels. At concentrations prevalent in tunnels NO is not itself a harmful pollutant and has no purpose as a control parameter. It has been used to infer NO2 levels in the absence of low cost reliable NO2 sensors. NO2 cannot be inferred from the measurement of NO. To infer NO2 from NO measurements, the ratio of NO2/NO is taken to be 1:10. Recent tunnel test data shows that the ratio is actually variable to values greater than 1:3, resulting in serious under reporting of NO2 values. New measurement techniques makes NO2 a viable parameter for control. The Codel TunnelTech 205 has been tested and approved by CETU in France for the measurement in the range of 0 to 2ppm in road tunnels. The Codel TunnelTech 205 uses a far simpler Single Wavelength Optical Transmissiometer (SWOT). Recommendations for NO2 Limits World Health Organisation (2005) – Recommends an upper limit of 200μgm/m3 (100ppb) for a 1 hour exposure. PIARC (2000) – Exposure to levels higher than 500μgm/m3 (250ppb) for 30minutes can impact on the health of sensitive people. CETU France (Centre d’Etudes du Tunnels) – Following Circulaire 99.239 of 8 Juin 1999 (Ministière de la Santé) the following limits are recommended: 400ppb for 15 minutes – NO2 50ppm for 30 minutes – CO 90ppm for 15 minutes – CO NO2: NO Ratio Data from CETU illustrates the importance of NO2 for ventilation control. Traditional control parameters CO & visibility are significantly below control threshold levels; NO2 is persistently above the control threshold. The data also shows how the NO2/NO ratios vary from 1:20 to 1:3. Inferring NO2 levels from a measurement of NO is not reliable. A direct measurement of NO2 is essential for control. Typical Road Tunnel Pollution Levels Sensor Comparison Data CETU compared the output from the CODEL TunnelTech 205 NO2 against a chemiluminescence NO/NO2 analyser in month-long trials. The accompanying chart shows typical 5-days operational periods for each sensor and demonstrates the good agreement of our system against the standard analyser (Chemiluminescence principle is the reference method for NO/NO2 measurement).

For more information on How well are you controlling your NO2 in your Road Tunnel? talk to Codel International Ltd

Enquire Now

  Please wait...

Location for : Listing Title