For roofline projects, consider the Golden Oak 18mm uPVC Replacement Fascia Board - 5m. Selected option: 225mm. Use product code FMS225WGO when selecting or ordering this item.



Material: Premium lead-free uPVC with a dense inner core and durable outer skin for strength and longevity



Finish: Realistic Golden Oak woodgrain foil with Freefoam’s Colormax™ colour technology and Renolit Exofol™ film for excellent fade resistance



Thickness: 18mm solid board designed for full fascia replacement and capable of supporting gutter systems



Length: Supplied in 5 metre boards to reduce visible joins and provide a smooth, continuous roofline appearance



Application: Ideal for complete roofline replacements or new build installations where fascia renewal is needed



Maintenance: Virtually maintenance-free surface that resists warping, cracking, rotting and discolouration – no painting required



Weather Resistance: UV-stabilised and built to perform in all UK weather conditions including rain, frost and sun



Installation: Lightweight and easy to handle, cut and fix using standard tools – suitable for professionals and experienced DIYers



Available Widths:; 150mm; 175mm; 200mm; 225mm; 250mm; 300mm; 400mm.



Guarantee: 20-year manufacturer’s guarantee as standard, extendable up to 50 years upon registration with Freefoam



A roofline refurbishment is an opportunity to look at the fascia, soffit and rainwater fittings as a complete assembly. Before ordering, examine the condition of the existing material and determine whether the job requires capping, replacement or a finishing component. These are different tasks, and a neat outer finish should never be used to conceal decayed timber or an unresolved moisture problem behind the roofline.



Measure each straight run independently and note changes in height, external and internal corners, and junctions with neighbouring structures. The useful coverage of a board or trim may differ from its overall dimensions once joints and end details are included. A measured cutting schedule helps make better use of the lengths ordered and reduces the likelihood of needing another delivery midway through the work.



Plan how the fascia detail will meet the soffit and guttering. The relevant brackets, connectors, joints and end pieces must be compatible with the system rather than simply similar in appearance. If matching an older installation, compare a physical sample or the existing profile where possible, since the shape and shade of roofline products can vary between ranges and over time.



Roofline work needs suitable access and a safe working arrangement. Refer to the manufacturer's fixing positions, support requirements and movement allowances before any installation takes place. Where the fascia carries rainwater fittings or meets the roof covering, establish how those elements are supported and how water is directed away from the building. Resolve structural defects before fitting decorative materials.



For larger projects, prepare a list of materials and check quantities against the final measured layout. Group items by their intended position so that similar components are not confused during fitting. This also makes it easier to identify which sizes or finishes still need to be ordered if the design changes before the work is complete.



Before making irreversible cuts or alterations, compare the item with the actual installation and check the necessary clearances. Where the system instructions permit trial positioning, use it to assess the layout before final fixing. If a proposed change affects the product's function or compatibility, obtain advice specific to the item before proceeding.



Think about how the finished area will be accessed after the work is complete. If inspection, cleaning or replacement is likely to be necessary, consider whether the planned layout allows for it without disturbing unrelated materials. Follow the maintenance and access requirements for the particular system, especially where a component will be concealed by subsequent work.



For ordering purposes, use the product reference in this listing alongside the name and any selected option. A product family may contain several sizes or finishes, and the name shared by that family does not identify every individual version. Check that the reference on the order confirmation matches the item required, particularly when several similar components are being purchased for the same project.



Any project with particular performance or regulatory requirements should be checked against the relevant technical documentation. The catalogue description is useful for identifying the product, but is not a substitute for confirmation of suitability in the intended application. Seek clarification about any required rating, classification or guarantee that is not explicitly stated in the available product information.