Find The Needle Get Listed
FloPlast White 92.5° Access Bend

FloPlast White 92.5° Access Bend



When comparing products for your project, use the specifications for FloPlast White 92.5° Access Bend to check the required configuration. Use product code SP169W when selecting or ordering this item.



The 92.5 Degree Bend with Access Point is a practical and versatile component for soil and waste systems, combining a functional bend with a built-in access point. This innovative design makes inspection and cleaning tasks significantly easier, ensuring the system remains efficient and blockage-free. The white finish complements modern plumbing installations, offering a clean and professional appearance, while the durable PVC construction ensures reliable long-term performance.



Design and features.



92.5 Degree Angle: Provides a smooth directional change in soil and waste systems, maintaining optimal flow.



Integrated Access Point: Simplifies maintenance by allowing easy inspection and cleaning without dismantling the system.



Durable PVC Construction: Engineered to resist wear, impact, and environmental conditions for long-lasting reliability.



White Finish: Offers a clean, professional look that integrates seamlessly with modern pipework.



Benefits.



Ease of Maintenance: The access point eliminates the need for complex disassembly, saving time during inspections and cleaning.



Efficient Performance: Ensures smooth waste flow while reducing the risk of blockages and system inefficiencies.



Versatile Application: Suitable for residential and commercial drainage systems requiring easy maintenance access.



The 92.5 Degree Bend with Access Point is used for soil and waste systems that require regular maintenance. Its combination of functionality, durability, and ease of use makes it an ideal choice for ensuring efficient and hassle-free plumbing systems.



Start with a drawing of the complete drainage or rainwater run, including the positions where water enters, changes direction and leaves the system. A fitting should be selected to suit its particular position in that layout. Confirm the relevant nominal size and profile, since components with a similar appearance are not necessarily designed to connect to one another.



Consider how the system will be supported and how it can be inspected after installation. The required fall, joint arrangement and access provisions depend on the type of drainage system and its intended use. Establish those details from the applicable installation guidance before work begins. For underground or concealed work, check the surrounding ground or structure and the requirements for the completed system.



If the project involves replacing a damaged component, identify the existing manufacturer's range and connection type wherever possible. Measure the old fitting and the adjoining components, and check the cause of the original problem before replacing it. A new fitting may not resolve an issue arising from a blocked outlet, incorrect support or an unsuitable arrangement elsewhere in the run.



A complete system should be assessed for the expected flow and the conditions in which it operates. Where capacity or compliance is important, consult the published specifications or seek advice from a competent installer. Once the work is complete, check the connections and relevant access points in accordance with the system guidance and retain a record of the installed components for future maintenance.



For larger projects, prepare a list of materials and check quantities against the final measured layout. Group items by their intended position so that similar components are not confused during fitting. This also makes it easier to identify which sizes or finishes still need to be ordered if the design changes before the work is complete.



Think about how the finished area will be accessed after the work is complete. If inspection, cleaning or replacement is likely to be necessary, consider whether the planned layout allows for it without disturbing unrelated materials. Follow the maintenance and access requirements for the particular system, especially where a component will be concealed by subsequent work.



When the work is finished, retain the product reference and any instructions relevant to care and inspection. Use cleaning products and methods that are approved for the material and finish. If the item forms part of a larger assembly, follow the maintenance guidance for that assembly as well. Address any damage or changes in fit promptly rather than relying on cosmetic treatment alone.



Before making irreversible cuts or alterations, compare the item with the actual installation and check the necessary clearances. Where the system instructions permit trial positioning, use it to assess the layout before final fixing. If a proposed change affects the product's function or compatibility, obtain advice specific to the item before proceeding.

For more information on FloPlast White 92.5° Access Bend talk to Building Plastics Online Limited