Select the fitting to suit the pipework layout. The FloPlast Underground 100mm Chamber Riser is the product specified here. Use product code D820 when selecting or ordering this item.



100mm Chamber Riser – Enhanced Access and Flexibility for Underground Drainage Systems.



The 100mm Chamber Riser is designed to extend the height of underground drainage chambers, providing improved access and increased capacity for your drainage system. Ideal for deeper system configurations, this riser enhances the functionality and maintainability of underground chambers. Its robust PVC construction ensures durability and long-lasting performance in challenging underground environments. Compatible with FloPlast chamber bases and covers, this riser offers a secure and leak-proof installation, making it a practical solution for residential and commercial drainage applications.



Improved Access and Capacity.



By extending the height of drainage chambers, the 100mm Chamber Riser allows for easier access during inspections and maintenance. It also enhances the system’s capacity to accommodate deeper drainage layouts effectively.



Durable PVC Construction.



Made from quality PVC, this riser is designed to resist environmental pressures, including soil weight and moisture. Its robust construction guarantees reliable performance and reduces the need for frequent maintenance.



Seamless Compatibility.



Designed to integrate with FloPlast chamber bases and covers, this riser ensures a secure, watertight connection that maintains the integrity and efficiency of the drainage system. Its straightforward installation process makes it suitable for professionals and DIY users alike.



For a dependable and efficient solution to extend the height of your underground drainage chambers, choose the 100mm Chamber Riser. Its durable design, compatibility, and straightforward installation make it an essential component for optimising your drainage system.



Start with a drawing of the complete drainage or rainwater run, including the positions where water enters, changes direction and leaves the system. A fitting should be selected to suit its particular position in that layout. Confirm the relevant nominal size and profile, since components with a similar appearance are not necessarily designed to connect to one another.



Consider how the system will be supported and how it can be inspected after installation. The required fall, joint arrangement and access provisions depend on the type of drainage system and its intended use. Establish those details from the applicable installation guidance before work begins. For underground or concealed work, check the surrounding ground or structure and the requirements for the completed system.



If the project involves replacing a damaged component, identify the existing manufacturer's range and connection type wherever possible. Measure the old fitting and the adjoining components, and check the cause of the original problem before replacing it. A new fitting may not resolve an issue arising from a blocked outlet, incorrect support or an unsuitable arrangement elsewhere in the run.



A complete system should be assessed for the expected flow and the conditions in which it operates. Where capacity or compliance is important, consult the published specifications or seek advice from a competent installer. Once the work is complete, check the connections and relevant access points in accordance with the system guidance and retain a record of the installed components for future maintenance.



If the product is being purchased for a repair, record the existing item and its surroundings before removing anything. Photographs, measurements and manufacturer references can make it easier to compare the replacement with the original. Where an exact replacement is unavailable, check the implications of a different profile or specification for the remaining components, rather than assuming it can be substituted without changes.



Allow time to inspect the delivered materials before installation. Compare their identifying labels with the order and check for obvious damage or missing components. Keep items in the condition recommended by the manufacturer until they are needed, and avoid exposing finished surfaces to unnecessary damage during other building work. This is easier than discovering a problem once the materials have already been cut or fitted.



Any project with particular performance or regulatory requirements should be checked against the relevant technical documentation. The catalogue description is useful for identifying the product, but is not a substitute for confirmation of suitability in the intended application. Seek clarification about any required rating, classification or guarantee that is not explicitly stated in the available product information.