Select the fitting to suit the pipework layout. The FloPlast Underground 0-90° Double Socket Adjustable Bend is the product specified here. Use product code D560 when selecting or ordering this item.



Adjustable Bend 0 to 90 Degrees – Versatile Solution for Flexible Directional Changes



The Adjustable Bend 0 to 90 Degrees is a highly versatile fitting designed to provide flexible directional changes in underground drainage systems. With the ability to adjust between 0 and 90 degrees, this bend allows for customisation of drainage layouts, making it suitable for both residential and commercial projects. Its double socket ends ensure secure and watertight connections, while its robust construction guarantees reliable performance in even the most challenging underground environments.



Flexible Directional Adjustments.



This adjustable bend offers a seamless solution for achieving precise directional changes, allowing for smooth water flow without compromising the integrity of your drainage system. Its adaptability makes it suitable for a range of installations, from standard layouts to more complex designs.



Durable and Reliable Construction.



Made from quality materials, this adjustable bend is designed to resist harsh underground conditions, including pressure, moisture, and environmental stress. Its durable construction ensures long-lasting performance and little ongoing maintenance requirements.



Straightforward fitting with Double Socket Design.



Featuring double socket ends, this bend provides secure and straightforward connections to plain-ended pipes. The user-friendly design simplifies installation, making it a practical choice for professionals and DIY enthusiasts alike.



For a durable, flexible, and efficient solution to directional changes in your underground drainage system, choose the Adjustable Bend 0 to 90 Degrees. Its superior design and robust construction make it an essential addition to any drainage network, ensuring smooth flow and system reliability.



Start with a drawing of the complete drainage or rainwater run, including the positions where water enters, changes direction and leaves the system. A fitting should be selected to suit its particular position in that layout. Confirm the relevant nominal size and profile, since components with a similar appearance are not necessarily designed to connect to one another.



Consider how the system will be supported and how it can be inspected after installation. The required fall, joint arrangement and access provisions depend on the type of drainage system and its intended use. Establish those details from the applicable installation guidance before work begins. For underground or concealed work, check the surrounding ground or structure and the requirements for the completed system.



If the project involves replacing a damaged component, identify the existing manufacturer's range and connection type wherever possible. Measure the old fitting and the adjoining components, and check the cause of the original problem before replacing it. A new fitting may not resolve an issue arising from a blocked outlet, incorrect support or an unsuitable arrangement elsewhere in the run.



A complete system should be assessed for the expected flow and the conditions in which it operates. Where capacity or compliance is important, consult the published specifications or seek advice from a competent installer. Once the work is complete, check the connections and relevant access points in accordance with the system guidance and retain a record of the installed components for future maintenance.



When the work is finished, retain the product reference and any instructions relevant to care and inspection. Use cleaning products and methods that are approved for the material and finish. If the item forms part of a larger assembly, follow the maintenance guidance for that assembly as well. Address any damage or changes in fit promptly rather than relying on cosmetic treatment alone.



Think about how the finished area will be accessed after the work is complete. If inspection, cleaning or replacement is likely to be necessary, consider whether the planned layout allows for it without disturbing unrelated materials. Follow the maintenance and access requirements for the particular system, especially where a component will be concealed by subsequent work.



For larger projects, prepare a list of materials and check quantities against the final measured layout. Group items by their intended position so that similar components are not confused during fitting. This also makes it easier to identify which sizes or finishes still need to be ordered if the design changes before the work is complete.