DC V 600.0mV / 6.000 / 60.00 / 600.0 / 600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV / 6.000 / 60.00 / 600.0V) ±0.8%±3dgt (600V) AC V 6.000 / 60.00 / 600.0 / 600V (Input Impedance: 10MΩ) ±1.0%±3dgt (6.000 / 60.00 / 600.0V) ±1.5%±3dgt (600V) DC A 600 / 6000μA / 60 / 600mA / 6 / 10A ±1.2%±3dgt (600 / 6000μA / 60 / 600mA) ±2.0%±5dgt (6 / 10A) AC A 600 / 6000μA / 60 / 600mA / 6 / 10A ±1.5%±4dgt (600 / 6000μA / 60 / 600mA) ±2.2%±5dgt (6 / 10A) Ω 600Ω / 6 / 60 / 600kΩ / 6 / 60MΩ ±1.0%±2dgt (600Ω / 6 / 60 / 600kΩ / 6MΩ) ±2.0%±3dgt (60MΩ) Continuity buzzer 0~600Ω (Buzzer sounds below 100Ω) Diode Check 2.8V Release Voltage:Approx. 0.4mA Test Current Capacitance 40 / 400nF / 4 / 40 / 400 / 4000μF Frequency 10 / 100 / 1000Hz / 10 / 100 / 1000kHz /10MHz DUTY 0.1~99.9% (Pulse width/Pulse period) ±2.0%±2dgt (~10kHz) Temperature -50~300ºC (-58~572ºF) (with the use of Temperature probe 8216) Note: KEW 1011 can measure max. 700ºC In order to measure over 300ºC, please use a K-type temperature probe available in the market. Display 6040 Counts Withstand Voltage AC 3700V / 1min Reading Type Averaging Applicable Standard IEC 61010-1 CAT.III 300V Pollution degree 2 IEC 61010-1 CAT.II 600V Pollution degree 2 IEC 61010-031 IEC 61326 Power Source R6P(1.5V) × 2 (Auto-power-OFF within 15 minutes) Dimensions 161(L) × 82(W) × 50(D)mm Weight Approx. 280g. Optional KEW8112 Clamp adaptor for digital multimeters Calibration Certificate.