Find The Needle Get Listed
Kew Loop Check 107
[KewLoopCheck]
LOOPCHECK 107 SEE Manual in the Information Box on the left Advanced socket tester with loop check, RCD and mains polarity Socket polarity test Loop check RCD check Mains polarity SKU: LOOPCHECK 107 The electrical safety council recommend the use of advanced socket testers, the LOOPCHECK 107 goes one step further… Standard socket testers – checks the wiring configuration at the socket but cannot tell if there is a neutral/earth swap! 2. Though a standard socket tester indicates whether the socket connections are correctly positioned, it cannot tell you if your earth connections are safe! The LOOPCHECK 107 conducts an earth loop test to indicate the quality of the earth loop. 3. If your mains polarity has been switched at the incomer, your standard socket tester cannot indicate this as the voltage difference between the plug pins are the same. By touching the test pad the LOOPCHECK 107 can indicate this very dangerous situation! 4. 30mA RCD test. And that’s why the LOOPCHECK 107 is the most advanced socket tester on the market. KEY BENEFITS Checks the quality of the earthing that is essential for safe installations Correct socket outlet wiring check Checks for the polarity of the mains supply Checks RCDs with measured current KEY FEATURES: Bright LED indication Audible tone indication This socket tester checks the important parameters for safe wiring, it places a cost effective solution in the hands of many more users at the front end of responsibility and care. Traditional socket testers check for the correct polarity at the socket outlet under test. They can tell if the earth path is missing but cannot check whether the path is of good enough quality to be safe. The loop check 107 does. Operation is easy. After being inserted in to a socket it will automatically run a wiring check, green LEDs will light and a continuous tone indicate a satisfactory result. Any faults will be highlighted by red and orange LEDs and a warble tone. The LEDs are positioned to represent the polarity of the pins. This gives another quick visual indication of where the fault lies. Having determined the socket polarity is good the tester will then test for the quality of the earth loop. This test is conducted at mains frequency. One of three different colour LEDs will light indicating the condition of the earth loop return path. The Loop check 107 also has the ability to check for the correct polarity of the mains supply. If this is wrong then a very hazardous situation exists. By touching the left hand touch pad the correct polarity of the mains supply is verified. The right-hand test button puts out a measured tripping current to check the operation of 30mA RCDs. LOOPCHECK 107 - Advanced socket tester from Kewtech • Checks correct socket outlet wiring • Checks the quality of the earthing that is essential for safe installations • Checks for the polarity of the mains supply • Checks RCDs with measured current

For more information on Kew Loop Check 107 [KewLoopCheck] talk to 2000 Test Equipment Ltd

  Please wait...

Location for : Listing Title