Find The Needle Add My Company
T&R 100A/E Mk3 100A SCITS
The T&R 100A/E Mk3** unit is portable, compact and simple to use. The mains supply for the unit is either 240V+10% or 115V +10% -6% at either 50 or 60Hz. Full load can be obtained at the supply voltage extremes. The current and voltage outputs are independently controlled and metered. The output current and voltage are displayed on large, clear panel instruments. An additional four range CT is provided, extending the ammeter range down to 0-100mA. The current output on the 100A/E Mk3 has eight ranges, allowing the selection of output voltages up to 150V and output currents up to 200A. The current outputs may also be used as voltage outputs. All of the outputs are fully isolated by means of double wound transformers. The type 100A/E MK3 S.C.I.T.S. is housed in a robust steel case, complete with fold away carry handles. The unit is fitted with a detachable cover in which is housed the spare fuse carrier and rating/scale factor plate. ** If using a 100ADM-F with this unit then you will need to order A006-0010 output lead set. FEATURES: Wide range of output currents. AC and DC voltage outputs. All outputs continuously variable. Output current metering from 40mA - 200A. Automatic switch-off in all modes of operation. Multi-function timing system. Suitable for testing thermal devices. Compact and highly portable. Voltage and current outputs available simultaneously. T&R 100A/E Specifications Current Output Range Continuous 5 Minutes 1 Minute VAC 200 A 50 A 100 A 200 A 0-5 V 50 A 25 A 50 A - 0-10 V 25 A 12.5 A 25 A - 0-20 V 10 A 5.0 A 10 A - 0-50 V 5.0 A 2.5 A 5.0 A - 0-50 V 2.5 A 1.25 A 2.5 A - 0-50 V 1.0 A 0.5 A 1.0 A - 0-150 V Voltage Output Voltage Output Current Range Continuous 5 Minutes 0 to 250 V AC 0.5 A 1.0 A 0 to 500 V AC 0.25 A 0.5 A 0 to 250 V DC 0.5 A 1.0 A Metering Range 1A Scale 5A Scale Accuracy 0.1 A x 0.1 x 0.02 Class 1.5 0.25 A x 0.25 x 0.05 Class 1.5 0.5 A x 0.5 x 0.1 Class 1.5 1.0 A x 1 x 0.2 Class 1.5 2.5 A x 2.5 x 0.5 Class 1.5 5.0 A x 5 x 1 Class 1.5 10 A x 10 x 2 Class 1.5 25 A x 25 x 5 Class 1.5 50 A x 50 x 10 Class 1.5 100 A x 100 x 20 Class 1.5 200 A x 200 x 40 Class 1.5 Timing System Range 0 to 999.999s. Resolution 1ms. Accuracy +0.1% rdg + 2d (all modes except current op.) Accuracy +0.1% rdg +3d (current operated mode). Functions Mode Timer Start Timer Stop Internal Start Press On Contact 1 Single Contact Contact 1 Contact 1 Dual Contact Contact 1 Contact 2 Current Operated Current > 20% of range Current <20% of range Protection and Safety Input Supply T5 A 240 V supply T10 A 115 V supply. Output Supplies T3.15 A. Contact F0.25 A. Auxiliary CT Circuit T315 mA and T1.25 A. Supply Requirements 115V + 10% - 6%: 50/60 Hz 1ph 1450 VA max 240V + 10%: 50/60 Hz 1ph 1450 VA max. Temperature Range Storage -20 to 60°C. Operating 0 to 45°C. Other Specs Dimensions 490 x 300 x 300 mm. Weight 33 kg.

For more information on T&R 100A/E Mk3 100A SCITS talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title