Fluke 5627A-12-X Precision Industrial RTD Probe
*** Please Note: When ordering also specify the termination you require, ie. Fluke 5627A-12-G (gold pins), plus the Bending Radius required. X = termination *** Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “I" (INFO-CON for 1521 or 1522), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). All models come without calibration unless calibration is purchased separately. The Platinum Resistance Thermometer (PRT) models 5627A is designed to be a secondary standard interpolating instrument converting temperature to resistance. The 5627A may also be used as a temperature standard for calibration of industrial sensors. The PRT is used with a readout device to detect temperature changes or actual temperature. The Fluke 5627A-12-X is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order). Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer, lab code 200706-0. FEATURES: Secondary PRT, 305 mm x 6.35 mm (12 in x 1/4 in), -200 °C to 420 °C. Vibration and shock resistant. NVLAP-accredited calibration included, lab code 200706-0. Bending Radius: Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. Fluke 5627-12 Specifications Resistance Nominal 100 Ω. Temperature Coefficient 0.00385 Ω/Ω/ °C nominal. Temperature Range ?200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C). Drift Rate (k=2) + 0.04 °C at 0 °C after 100 hours at 420 °C. Sheath Material 316 Stainless Steel. Leads PTFE-insulated, nickel-plated stranded copper, 22 AWG. Termination Specify. See Ordering Information. Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps. Bending Radius Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.). Calibration Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9). ITS-90 coefficients included. Immersion At least 100 mm (4 in) recommended. Calibrated Accuracy? (k=2) + 0.026 °C at -196 °C + 0.046 °C at 0 °C + 0.077 °C at 200 °C + 0.124 °C at 420 °C. Dimensions 305 mm x 6.35 mm (12 in x 1/4 in). ?Includes calibration uncertainty and 100 hr drift.

For more information on Fluke 5627A-12-X Precision Industrial RTD Probe talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title