Find The Needle Add My Company
Chauvin F401 AC TRMS Clampmeter
To deal with the highest level of low-voltage electrical installations, the Chauvin F400 Series has a high protection rating and is ideal for maintenance, testing, monitoring and diagnostics on medium-power installations. Equipped with a fast 12-bit TRMS digital acquisition system, the Chauvin F401 clamp offers particularly accurate measurements whatever the signal's waveform. Automatic AC/DC detection is a standard feature on all the models in this range, as is IP54 protection. FEATURES Clamping diameter: 48 mm. Current: 1,000 A AC. AC and DC voltage up to 1,000 V. Resistance and audible continuity. Temperature. Automatic AC/DC detection. TrueInrush current measurement. Hold, Min, MAX. CAT IV 1,000 V. IP54 protection rating. Chauvin Arnoux F401 Specifications Clamping Diameter 48 mm. Display Backlit LCD. Resolution 10,000 counts. Number of Values Displayed 1. Type of Acquisition TRMS (AC). Autorange Yes. AC Current AC Current Range 0.15 to 1000 A (1500 A peak). Best Accuracy 1% reading + 3 cts. Frequency Range Current: 5.0 to 2000 Hz Voltage: 5.0 to 20.00 kHz. Resistance Range 0.1 to 99.99 kΩ. Open Circuit Voltage ?8 V. Measurement Current ?680 µA. Audible Continuity Continuity Threshold Adjustable from 1 to 999. Diode Test Yes. Temperature Range -60.0 to 1000°C (-76.0 to 1832°F). General Dimensions 92 x 272 x 41 mm. Weight 600 g. Chauvin F401 warranty 3 years.

For more information on Chauvin F401 AC TRMS Clampmeter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title