Find The Needle Add My Company
Amprobe HD160C Heavy-Duty Digital Multimeter
The Amprobe HD160C digital multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistance to at least eight feet. The HD160C is a heavy-duty 4-digit, autoranging, AC-coupled True RMS measuring instrument that measures voltage, current, resistance, continuity, as well as capacitance, frequency and temperature. It also offers Range Lock, Data Hold, Relative Measurement, Auto Min Max Measurement, a bright backlight, and Auto Power Off to save battery life. The instrument is completely o-ring sealed to pass strict IP-67 ratings for moisture and dust proof. The HD160C meets the highest safety rating of CAT IV 1000 V (1500V DC max). FEATURES Highest voltage capability, measuring to 1500 Vdc and 1000 Vac. CAT IV 1000 V rated. Special sealing for environment and water resistance. IP67 rated. Constructed with drop-resistant housing and PCB mounting. Measures capacitance, temperature and frequency. Superior 10,000 count resolution with bar graph. Magne-Grip™ holster, frees both hands for workIncludes high voltage test leads with threaded alligator clips. Temperature measurement built-in. Frequency and capacitance. Digi-Glo™ bright backlight. Amprobe HD160C Heavy-Duty Digital Multimeter Video Amprobe HD160C Heavy-Duty Digital Multimeter Specifications General Specifications Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Polarity Indication Automatic. Input Overload Indication OL, -OL. Low Battery Indication Symbol at less than 50 hours battery life remaining (accuracy no longer guaranteed) Display Update Rate 2/sec nominal; 20/sec for bargraph Operating Temperature 0 to +50°C @ 0 to 75% RH. Storage Temperature -20 to 60°C @ 0 to 80% RH, battery removed. Temperature Coefficient 0.1 x (spec. accuracy)/°C (0 to 18°C and 28 to 50°C). Fuse F 2A/1500V fuse (8mm x 65mm), I.R. 30kA - Amprobe p/n FP700. Power Standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22. Auto Power Down Meter powers down after approximately 30 minutes of inactivity. Not in MIN/MAX function. Battery Life (typical) 150 hours, alkaline. Backlight usage consumes extra power and will decreased battery life significantly. Backlight auto off after approx 60 seconds. Dimensions (without holster) 200 x 102 x 59mm (7.9 x 4.0 x 2.3") - H x W x D. Weight (Incl. Battery) 642g (22oz). Case material Reinforced, high-impact, fire retardant thermoplastic. Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67. EMC Meets EN 61326-1. Electrical Specifications (Accuracy at 23 °C + 5 °C, Accuracy at 23 °C + 5 °C, <75 % RH, guaranteed for one year) DC Voltage Ranges 1000mV, 10V, 100V, 1500V. Resolution 0.1mV in 1000mV range. Accuracy +(0.1% rdg + 5 digits). Input Impedance 10MΩ. CMRR >120dB up to 1500V DC. NMRR >60dB at 50/60Hz. OL Protection 1500V DC or 1000V AC RMS. Transient Protection 12kV impulse (1.2µS/50µS) based on EN 61010-1:2001 impulse requirements for CAT IV 1000V/1500V DC products. This product should not be used in installations where transients exceed 12kV. AC Voltage (True RMS) Ranges 1000mV, 10V, 100V, 1000V. Resolution 0.1V in 1000mV range. Accuracy 1000mV (45 to 400Hz): +(1.2% rdg + 10 digits) 10V, 100V (45 to 500Hz): +(1.2% rdg + 10 digits) 10V, 100V (500Hz to 2kHz): +(2.0% rdg + 10 digits) 1000V (45 to 1kHz): +(2.0% rdg + 10 digits) Input Impedance 10MΩ. Conversion Type True RMS, AC coupled 5% to 100% of range. Crest Factor ?3 OL Protection 1500V DC or 1000V AC RMS. Transient Protection 12kV impulse (1.2µS/50µS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV. DC Current Ranges 100µA, 1000µA, 10mA, 100mA, 400mA, 2A (auto/manual ranging). Resolution 0.01µA in 100µA range. Accuracy 100µA range: +(0.5% rdg + 10 digits) 1000µA to 400mA ranges: +(0.5% rdg + 5 digits) 2A range: +(1.5% rdg + 10 digits). Input Protection 2A/1500V fast blow ceramic fuse 8 x 65mm on A input, FP700. Burden Voltage µA range of 1mV/1µA, mA range of 10mV/1mA, 2A range of 500mV/1A, 500mV max. (2V max on 1000µA, 100mA, 400mA, 2A ranges). OL Protection A input (F 2A/1500V, size 8 x 65mm IR fast blow ceramic). AC Current (True RMS) Ranges 100µA, 1000µA, 10mA, 100mA, 400mA, 2A. Resolution 0.01µA in 100µA range. Accuracy (45 to 1kHz) 100µA to 100mA: +(1.5% + 10 digits) 400mA: +(2.0% + 10 digits) 2A: +(2.5% + 20 digits). Voltage Burden See DC current. Conversion Type True RMS AC couple 10 to 100% of range. Crest Factor ?3. OL Protection See DC current. Resistance Ranges 1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ. Resolution 0.1Ω in 1000Ω range. Accuracy 1000Ω to 1000kΩ: +(0.5% rdg + 8 digits) 10MΩ: +(1.0% rdg + 10 digits) 40MΩ: +(2.0% rdg + 10 digits). Overload Protection (All Ranges) 1500V DC or 1000V AC RMS. Continuity Audible Indication Less than 40Ω. Response Time 100ms. Overload Protection 1500V DC or 1000V AC RMS. Capacitance Ranges 40nF, 400nF, 4µF, 40µF, 400µF (3999 counts) - auto/manual ranging. Resolution 0.01nF. Accuracy 40nF, 400µF: +(3.0% rdg + 10 digits) 400nF to 40µF: +(3.0% rdg + 5 digits). Test Voltage <1V. Test Frequency 1.3Hz on 40nF to 40µF ranges; 0.7Hz on 400µF range. Overload Protection 1500V DC or 1000V AC RMS. Temperature Ranges -20 to 1300°C (-4 to 2372°F). Resolution 1°C, 1°F). Accuracy -20 to 10°C: +(2.0% rdg + 4°C) 10 to 200°C: +(1.0% rdg + 3°C) 200 to 1300°C: +(2.0% rdg + 2°C). Frequency Ranges 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz. Resolution 0.01Hz on 100Hz range. Accuracy +(0.1% rdg + 5 digits). Sensitivity 3Hz to 1mHz: >2.5V AC RMS 1mHZ to 10mHZ: >2.5V AC RMS, <5V AC RMS. Minimum Input Range 100Hz range: >3Hz 1000Hz range: >30Hz. Minimum Pulse Width >25ns. Duty Cycle Limits >30% and <70%. Overload Protection 1500V DC or 1000V AC RMS .

For more information on Amprobe HD160C Heavy-Duty Digital Multimeter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title