search

Oxygen Detectors: What Is An O2 Depletion Monitor?

Oxygen Detectors: What Is An O2 Depletion Monitor?
09/03/2021

Oxygen Detectors: What Is An O2 Depletion Monitor??

Oxygen (O2) depletion monitors are devices capable of measuring the ambient concentration of atmospheric oxygen and signalling when Ievels have fallen. This can enable action to be taken before an evacuation is required and levels become dangerous. In addition to oxygen depletion, problems arise when oxygen levels are too high. This oxygen “enrichment” (levels above 23%) can be dangerous; increasing the chances of combustion and the intensity of fires. In summary, oxygen detectors can signal all dangerous levels of oxygen and are important instruments for a range of applications.

Understanding Oxygen Enrichment & Depletion In the atmosphere, oxygen is present at around 20.9% (at sea level), with substantial fluctuations either side of that percentage having the potential to cause disaster. Although, it can be misleading to discuss percentages of oxygen without considering atmospheric pressure. For example, atop a mountain where the atmospheric pressure is low there will be less oxygen than at sea level where atmospheric pressure is relatively higher, even though the percentage of oxygen will be the same in both cases. Accordingly, oxygen levels are commonly discussed in reference to partial pressures.

TOC-750 Oxygen Detector Introducing O2 Depletion Monitors O2 depletion monitors are recommended in areas where oxygen levels are determined, through a risk assessment, to fall at any point below 19.5% Vol. These include areas where inert or other asphyxiating gases are present or in confined spaces or where significant amounts of carbon dioxide (CO2) are in use. However, it is important to note that when CO2 is suspected of displacing oxygen, CO2 toxicity is a far greater concern and a CO2 monitor should be installed. Nonetheless, O2 depletion monitors are commonly used in research and teaching laboratories and industries that handle nitrogen, helium and argon, such as those involved in manufacturing, food and electronics. Sensors for oxygen detectors are placed in areas at risk and at elevations based on the displacing gases vapour density.

portable oxygen detector Pictured: Senko SGT-P Maintainable Oxygen Portable Detector. Available to Purchase Online Here. Installing Oxygen Detectors for O2 Depletion Monitoring Under the conditions described above, installation of O2 depletion monitors is imperative because reductions in ambient oxygen can quickly lead to oxygen starvation, which can impair mental and physical ability and so increase the likelihood of accidents and injuries. Furthermore, significantly low levels of oxygen (12% and lower) can rapidly induce unconsciousness, potentially leading to fatalities. If you are using portable monitors for confined space entry, it is important that battery power has been checked, and the instrument must be in calibration and bump tested before use.

Traditional oxygen sensors use lead-based sensor technology that degrades over time. This leads to a gradual inability for the cell to produce sufficient signal output, which will eventually cause the sensor to drift below the alarm point and trigger. Here, recalibration of the device is a common solution, however, this will only be a temporary fix. To circumvent the issues surrounding lead-based cells, International Gas Detectors Ltd. have developed oxygen detectors based on solid polymer technology. This advanced method is not consumptive and has the added benefit of being RoHS compliant. The sensors offer competent oxygen monitoring with extended lifetimes in excess of 5 years, between 5 and 10 times longer than typical lead-based consumptive sensors. Although seeming purely a product specification benefit, this change has a marked effect upon nuisance alarms and their eradication.

Enquiry Form



More News

Low-Temperature Ammonia Detection In Industrial Refrigeration Applications

Low-Temperature Ammonia Detection In Industrial Refrigeration Applications

Gas safety is an important consideration for any refrigeration application.1 One of our Mechanical & Electrical (M&E) partners, Livewire Mechanical & ...

Read More
A Case Study In Gas Building Solutions From IGD

A Case Study In Gas Building Solutions From IGD

Boiler House Case Study A UK company approached IGD to look at possible solutions to gas detection issues following a potentially serious incident on...

Read More
IGD’s Revolutionary 2-Wire Addressable Room Status Indicators

IGD’s Revolutionary 2-Wire Addressable Room Status Indicators

At IGD we are often asked for room entry status indicators to show if it is safe or not to enter an area protected by our gas detectors. In many cases...

Read More

Read More

Read More

List your business

Would you like to register your company on one of the UK's largest and most effective Trade websites?

Are you looking for a reliable and consistent source of enquiries from your industry sector? Would you like to see why Find the Needle clients come back year after year to use our service? If so then feel free to register using the link 'here'.

Register
Office Address: